Factory Direct Sales Hgl Series 63A 400V Load Isolation Switch
- Apr 22, 2018 -

Basic Info

  • Model NO.: HGL 63/3

  • Structure: Double-column Disconnector

  • Operation: Manual

  • Movement Mode: Horizontal Rotary Type

  • Grounding: Un Grounded

  • Run: Turn the Horizontal

  • Common Model: Hgl

  • Certification: CE

  • Manufacturers: Yes

  • Changeover: Changeover Between Two Load Equipment.

  • Full Bypassing Isolates The Equipment: From Upstream and Downstream Currents

  • Transport Package: Export Carton and Wooden Tray

  • Origin: China

  • Type: Low-voltage

  • Installation: Indoor High-voltage

  • Grounding Mode: Not Grounding

  • Number of Poles: Three Pole

  • Series: Three

  • Switching Mode: Double-Throw Type

  • Structure of Operating: Manual

  • Brand: Lovadon

  • Power Supply Changeover: Main Power Supply Changeover to Standby Power

  • Reverse: Reversion by Two Phases Changeover.

  • Trademark: LOVADON OR OEM

  • Specification: CE

  • HS Code: 8536500000


Operation mode
1Direct operation:The handle is installed directly in the middle of the switch.
2Operation outside the board:The handle is installed outside the door off distributing board.
363A-100A is suitable for the making and breaking of electrical isolation circuit or electric insulation. 
463A-100A posseses three poles,and four poles(three poles+on off neutral pole.)
5Two sets of auxiliary contacts can be assembled according to demand.
6Side operation,operation outside,the board can be assemble according to demand.
Operation load isolation switch behind the HGL-160A~1600A/H board
1160A-1600A is stuitable for the making and breaking of electricl isolation circuit or electric insulation.Those over In 1,000A are only suitable for electric isolation.
2160A-1600A possesses three poles, and four poles(three poles+on -off neutral pole).
3Observation window for products below 630A can be provided according to the demand to observe directly the on and off state of the contact.
4Two sets of auxiliary contacts can be assembled according to demand.
5Mechanical property and electric property correspond to the mechanical property and electric property of HGL-160A~1600A.
Noteonly offer products for operation outside the board.
Connection load isolation switch behind HGL-160A~1600A/B board.
1160A-1600A is suitable for the making and breaking of electric isolation.Over In 1,000A are only suitable for electric isolation. 
2160A-1600A has three poles,and four poles(three poles+on-off neutral pole).
3Observation window for products below 630A can be provided according to the demand the on and off state of the contact.
4Two sets of auxiliary contacts can be assembled according to the demand. 
5Mechanical performance and electric performance correspond to the mechanical property and electric property of SGL-160A~1600A.
HGLC-160A~1600A side operation load isolation switch
1HGLC-160A~1600A.The load isolation switch is suitable for the making and breaking of circuit or electric isolation.The products have three pole,four pole(three poles+on-off neutral pole)Switches over1000A are only suitable for Electric isolation. 
2Observation window can be provided for products below 630A can be provided according to the demand to observe directly the on and off state of the contact. 
3Mode of operation: Direct operation:handle is installed on the right side of switch.
Operation outside the board:handle is installed outside the door of distributing board. 
4Two sets of auxiliary contacts can be assembled according to the demand. 
5Extended shaft is used for the operation outside the board.
6Mechanical property and electric performance correspond to the mechanical performance and electric perfomance of HGLC-160A~1600A.
7The electric cable insulating cover can be assembled.
HGLZ-125A~1600A change over load isolation switch
1HGLZ-125A~1600A.The load isolation switch is suitable for the change-over of two sets of low voltage electric circuit or the change-over of 2 set of load devices or safety isolation.
2Mode of operation:
Direct operation: handle is installed on the switch.
Operation outside the board: handle is installed outside the door of power distributing board
3Products with observation windows can be provided according to the demand to observe directly the ON and OFF state of contact.
4The products have three poles,four poles, and(three pole+ON and OFF neural pole).
5Extended shate is used for there operation outside the board.
6Two sets of auxiliary contacts can be assembled according to the demand.
7Mechanical performance and electric property correspond to the mechanical performance and electric property of HGL-125A-1600A.
8A bridge can provided to connect the inlet or outlet terminal of the switch.
9the electric cable insulating cover can be assembled 
   NoteThe bridge connection is chosen, an explanation is needed to indicate there indicate the inlet or outlet connected with it