Model No. | H-SA-01 |
Description | Zigbee Smoke Sensor |
Power Supply | Battery (CR123A, 3VDC) ---1400mAh |
Battery Life | > 1 year |
Alarm Function | 1.Sound/Light Alarm 2.Alarm indicator shown on App |
Self-Test | Alarm Sound with LED flashed 1.Local: Pushbutton for self-test. 2.Remote: Triggered by APP. |
Low Voltage Indicator | At least indicate low voltage of battery once every minute for 7days. 1.Local: YELLOW LED Flashed at 53s interval, and give out a sound (‘Di’) for indication. 2.Remote: shown on APP. |
Low Voltage Warning | Able to send continuous alarm signal for at least 4 minutes after 7 days low voltage. |
Local | RED LED Flashed |
Battery monitoring period | <=24Hours |
Muted time | <100s |
Sound Pressure Level (dB) | >80dB @ 3meter distance |
Interlinked Alarm | Master Alarm, Slave alarm triggered together |
RF Standard | 2.4GHz, IEEE 802.15.4, ZigBee-PRO standard, ZigBee 3.0 protocol certified |
RF Effective Range (Zigbee) | Indoor line-of sight range >30 meters |
RF Solution Platform (Zigbee) | Silicon Labs, EFR32MG13 |
Detective Range | >30 square meters |
MAX RF Tx power | <10dBm |
Operating Temperature | -10 °C to 45 °C |
Operating Humidity | 0 ~ 85%RH, no condensing |
Storage Temperature | -25℃~75℃ |
Storage Humidity | 10%-95% RH, no condensing |
IP Rating | IP41, indoor only |